SHARP, volume reduction + analog amount minus, boot. .


Plus can be turned in the time menu, press the remote control to turn ON for 5 seconds.


Not directly by the state machine to open the remote turn ON 25 秒. .


EPSON light bulb clear method: has capacity of 100MA fuse. instant shorted. .OK! MITSUBISHI bulb zero method: (left + right) + ENTER.


Sharp 300S, 300X is also pressing the remote control ENTER, down arrow, left arrow and then press the ON boot. .


Mitsubishi zero is S250. up arrow + ENTER + startup key.


Following methods without validation: Panasonic: MENU --- lamp usage time ---- ENTER [3S] Hitachi: RESET [3 秒] PHILIPS: election to the bulb time field, press OK3 seconds Toshiba: No power supply is [the power button + Menu + OK + Enter] to continue to hold it then press 3 seconds after the power has no right welcome corrections! ! ! . .


Hitachi long press and hold the RESET after displaying a dialog box to select OK.


BenQ press the power button followed by the power supply. .


Epson projector zeroing method is only applicable with lamp resistance) of the machine: the lamp stand at a low resistance (zero by), as long as the machine corresponds to a four small pin shorted out, this is annoying, and short circuit could not well be possible to burn in Board;.


Morningstar TL460 projector reset lamp timer method. .


Hold down the projector + and AUTOSYNC on button press the projector ON and on the UNDC-button after the startup screen, 0000.


Panasonic projector clear way: press "MENU" to find light bulbs to use, then press "ENTER" three seconds, there "POWER OFF" after the power switch to restart OK. .


3M MP8030 zeroing is to press the TIMER button for two seconds, a dialog box that appears, select zero.


3M8746 clear: press RESET display lamp time, press the left right to move the cursor to 0000, while left-right to make the menu disappear, OK! . .


Fujitsu: press the OK key + press the power key three times [for part of the machine].


Yuan Epson technical information VD:. .


Lamp usage time zero problem:.


BY POKEMON13. .


For most of the newer models (frame without any testing components), only in the maintenance of the State is cleared to zero. The State at the same time by pressing the "HELP?" and "escalator school +" until you reach the maintenance mode menu, the menu displays the content including the total use time machine, replacement bulbs, post count, graceful shutdown times, current time data using the bulb. If you want to put the lamp time is cleared to zero, you can now press the "ENTER" and "escalator school +" can be used on the lamp time is cleared to zero.


For most of the older models (Lighthouse has detected a new fuse bulb), can only be cleared by hardware. The principle is: Stands with a new lamp detection 100mA fuse, the fuse is installed because the pass, the power is triggered when the internal lamp usage time counter to zero. At the same time in the fuse in the boot upper between Shun had a large current to fuse has blown. At this point the machine into normal operation. Therefore, if the renewal light bulb usage time automatically zero.If you cannot find the fuse 100mA, where both ends can be shorted fuse, power on after power on after power-on-the-fly, immediately unplug the power, remove the short wiring, often zero success!.


Sanyo SU31 on the last item in the menu, there is a light bulb in the next step clear 0, Select YES if you can pull. .


Philips projection method: post is cleared to zero, the menu, select the time bar by lamp projectors on the OK button for 3 seconds.


Sharp 100S/00X/200/220 and so on, the projector bulb clear way, the standby, press and hold -, +, AUTOSYNC three keys, after the boot. .


AN100S AN100X AN120S and hold (standby state) on the projector; +; and AUTO SYNC, press ON and on the projector;-; button if the display shows that the lamp has been LAMP0000H reset.


sharp DLP projector clear: standby press the "right" + "down" + "enter" + "power" can be. .


Sharp video machine (PN200/300/500/C10) bulb zero time, press and hold standby reduced under the "volume" + "select", after the boot;.


CN450S CN450X CN500X clear way: a state in standby (not boot) and press the projector; INPUT ENTER UNDO ON 3 seconds he will be able to boot. If the display; light bulbs to 100% clear on that. .


SONY P15 projection bulbs clear methods in the light of the State press RESET after you press the left button and pressing the according button N is also a confirmation key 7 seconds.


U.S. open to Menu + OK. .


Fujitsu left + right +.


Epson 730 projector clear way. .


Help key and trapezoid correction ' minus ' keys at the same time, the maintenance menu appears, key and confirm the trapezoidal correction while pressing the keys can be cleared to zero, you must have a signal before the operation.


Hitachi projector clear method: boot, press the RESET Kin 3 seconds, the time the dialogue appears, select 0. .


Epson 3300 3500 zeroing method 1. dozen open lights soak □o hood, look out bubble has 鎖 緊, or lights make bubble long required.


2. . Whether the new light bulb to re-set after installation without them. To re-set the machine there are two kinds: EMP-3300: After the lock on the light bulb cover, this time on the projector while Anzhe Sync keys Menu and then turn on the power after five seconds then release Menu and Sync two keys, you can reboot.EMP-3500: soak the lights on after install bubble 鎖 good protection cover, this time with the time according to the projection machine on Tracking + and + button to not Sync again will supply source to play after five seconds to open, and then open Tracking + and Sync + 2 button, you can open machine, machine sorts are not be established.


LG Projector lamp reset button 5 seconds, press up, pop-up menu, and then add the right touch the main course. .


Panasonic。.


Press "MENU" to find light bulbs to use, then press "ENTER" 3 seconds, there "POWER OFF" after the power switch to restart. .


Mitsubishi Projector X490: left + right + POWER.


3 Ling XD350U, under the boot (power indicator light.. LAMP lights are solid red, the) key and press the OK button. .


COMPAQ1600 press RESET30 seconds!.


Sharp XR11 press the power button and the down button and OK. .


Sharp 200/220, projector bulb zero method, press standby-, +, AUTOSYNC three key after the power-on,;.


CN450S CN450X CN500X clear way: a state in standby (not boot) and press the projector; INPUT ENTER UNDO ON 3 seconds he will be able to boot. If the display; light bulbs to 100% clear on that;. .


AN100S AN100X AN120S and hold (standby state) projector + and AUTO SYNC, press on the projector ON and-button if the display shows that the lamp has been LAMP0000H reset.


sharp DLP projector clear: standby press the "right" + "down" + "enter" + "power" can be;. .


SHARP NV21 series zero means: do not power off, press the direction right, bottom, OK, continue to hold down for 5 seconds after the jump.


Hitachi right arrow for 3 seconds. .


Guarding the projector bulb zero 228 method is simple, select a bulb on the menu, and then select OK on the line.


Morningstar TL460 projector reset lamp timer method. .


Hold down the projector + and AUTOSYNC on button press the projector ON and on the UNDC-button after the startup screen, 0000.


Philips: Menu - lamp time, press the OK button for 3 seconds. .


EPSON EMP-S1 bulb zero: go to menu, select Reset, and then select Reset the lamp timer, press the OK button and choose YES you can.


Panasonic TV after boot holding down the VOL-pressing the remote control on the MULTI PIP more than five seconds OK. .


There is a SONY, left + right + REST!.


Mitsubishi LVP-X80U reset: power on, and press the left and right and the power button. .


Morningstar CX490/500/600/610 zeroing: power-on, connected to the signal source, enter the menu, press the arrow keys to enter the input message status, use the "+" button to reset the time, to confirm exit.


SANYO (Sanyo) projector clear way. .


All in the menu, there is a LAMP (bulb), all of the words "this column is YES.


The brand projector clear large FA! . .


1, Panasonic (Matsushita) projector zeroing method zero Panasonic projector: first press the "MENU" to find the lamp usage time, and then press the "ENTER" in three seconds, the "POWER OFF", turn off the power to restart OK!.


2, Epson (Epson) Epson projector projector clear clear method method (for Lighthouse Service resistors) of the machine: the Lighthouse Service has a small resistance (clear use) as long as the machine the corresponding short-circuit about 4 small pin on the line, this will be a little annoying, and will likely burn motherboard short circuit Nongbu Hao. .


3, Toshiba (Toshiba) projector is cleared to zero means zero: Toshiba projector without power by power + menu + OK + enter and hold power for 3 seconds, which is applied to all previous 780; machine.


4, SHARP 500X bulb clear also by: INPUT, ENTER, UNDO. .ON 100% is the bulb is SHARP (sharp) projector is cleared to zero means sharp video machine (PN200/300/500/C10) bulb zero time, press and hold standby reduced under the "volume" + "select", after the boot; Sharpe 100S/00X/200/220, projector bulb zero method, press standby-, +, AUTOSYNC three keys, after the boot; Note: the machine behind the SHARP (2004 model) do not randomly is cleared to zero, the zero it replace the bulb or the lamp in the 200 hour will burst! . .


5, Epson projector zero zero method Epson 5600: press and hold the Help3 seconds, a dialog box appears, select OK to.


6, SONY (Sony) Sony projector clear way clear method: RESES + L + R + OK (for most Sony models);. .


7, INFOCUS (rich visual) and ASK (u vote for God), Proxima (Bao Shi MA), IBM projectors zeroing is typically in the menu; the rich visual 500/530-on, press menu + noise 3 seconds, after the open menu to see if there's a clear, if not you can try; IBM is OEM, INFOCUS INFOCUS; reference.


8, Hitachi (Hitachi) Hitachi projector projector clear way clear method: boot, press the RESET Kin 3 seconds, the time the dialogue appears, select 0 to OK a; back to the default: by opening the menu, press the RESET Jian 3 seconds, a dialog appears, click on (I forget what the letters, sorry)! . .


9, NEC (APR) projector zeroing method 830/840/850/440 series time to appear second indicator light, including the LAMP led, zero is standby OFF key pressed under 20 seconds or so, the bottom of the remote control has a headphone jack, so if the cable you can connect to the projector's remote control input, so it will be convenient to zero;.


10, Fujitsu (Fujitsu) projector clear method 7201 series of machines: press the OK button + press the power button three times without letting go. .


11, Mitsubishi (Mitsubishi) projector Mitsubishi Projector zero method zero method: in standby press left + right + power: what do you think of the light bulb using time? left + right + enter.


12, sharp DLP projector clear standby press the "right" + "down" + "enter" + "power" can be. .


13, 3M projector zeroing method zero Hitachi OEM 's: power-on RESET, press the key for 3 seconds and a time with dialogue, it would be nice to choose 0 MP8030 zeroing is to press the TIMER button for two seconds, a dialog box that appears, select zero.


14, Philips (Philips) Philips projector projector clear way clear method: boot, the menu bar lamp time, press the OK button on the projector for 3 seconds. .


15, SANYO (Sanyo), EIKI (love it), Canon (Canon) projector is cleared to zero all the way in the menu, there are the words of this LAMP, all is YES column Sanyo Z1 menu and input by five seconds to go in Factory mode select and input by five seconds into service mode Note: two added up to nearly a thousand items before you change settings, remember numerical copy factory.


16, PLUS (PLUS) projector clear method PLUS U2-811 U2-815 U2-815C U2-1110 U2-1130 U2-X1130C U2-1150 lamp at 1100 hours to clear the menu selection time by remote control device on the ON 8 seconds or so after using 1100 hours can not be turned on directly on the remote control ON 25 or so PLUS U3-810SFC U3-1080SFC U3-810WZC U3-1080WZC U2-X200UC 4-161 U4-121 V-1080C V- 807C V-1100C U2-850 U2-1500 U2-850W U2-1500W U5-121 U5-162 lamp timer reset menu。.


Clear the way for the projector lamp. .


1: SHARP, volume reduction + analog, 300S on Sharpe, 300X simultaneously pressing ENTER on the remote control, down arrow, left arrow, and then press down ON the post, you can have sharp DLP projector of zeroing: standby at the same time as the "right" + "down" + "enter" + "power".


2: PLUS energy turned on by remote control at the time the boot menu ON 5 秒. . Can not open state machine directly by remote boot ON 25 秒. .


3: EPSON 。.


4: MITSUBISHI bulb clear way: (L + R) + ENTER. . Mitsubishi S250 clear method is. . On the arrow + ENTER + Start button. .


5: Panasonic: MENU---bulbs use time-ENTER the [3S] Panasonic: first press the "MENU" to find the lamp usage time, and then press the "ENTER" in three seconds, the "POWER OFF", turn off the power to restart OK!.


6: Hitachi: RESET [3 sec]. .


7: PHILIPS: power, menu, press the time bar lamp projectors on the OK button for 3 seconds.


8: Toshiba: do not connect the power [the power button + menu + OK + Enter] Press and hold the power then continue after 3 seconds. .


9: BenQ press the power key after the power supply.


10: Morningstar TL460 on the projector press and hold the + and AUTOSYNC press the button on the projector and UNDC-ON button to start the screen after 0000. .


11: 3M MP8030 is press the TIMER button for two seconds, a dialog box that appears, choose zero can be displayed by pressing RESET 3M8746 long lamp time, press the left and right keys to move the cursor to 0000, and at the same time, press the left button to make the menu disappears, and OK.


12: Fujitsu: Press the OK button + press the power button three times without letting go [for part of the machine]. .


13: Sanyo SU31 is the last item of the menu, in the next room there is a bulb-0, you just have to select YES, you can pull.


14: AN100S AN100X AN120S hold down (in standby mode) on the projector; +; and AUTO SYNC same time, press ON on the projector and; -; button if the display has been reset LAMP0000H that bulb. .


15: CN450S CN450X CN500X zeroing method: in the standby state (do not post), press the INPUT of the projector; ENTER UNDO ON more than 3 seconds to turn on his own. If you display; bulb 100% indicated to zero.


16 SONY P15 projector bulb clear method [reposted elsewhere〕 in the red light of the state, press RESET and press the left click is right and press the N key 7 seconds can be recognized. .


17: beauty from menu + OK.


18: Fujitsu L + R + Up. .


19: EPSON 。.


Clear Methods: The contents have been off the 100MA fuse. . Instantly shorted. . OK! Yuan Epson VD technical information: the lamp usage time cleared the problem: BY POKEMON13 for most of the newer models (truss element without any test), only in the maintenance of state cleared. Powered on simultaneously press the "HELP?" And "ladder schools +" until a maintenance mode menu, menu display, including the total use of machine time, the number of replacement bulbs, boot times, shutdown times, the current lamp usage time data.If you want to put the lamp time is cleared to zero, you can now press the "ENTER" and "escalator school +" can be used on the lamp time is cleared to zero. For most older models (lamp bulb for erecting a new detection of fuse), can only be cleared by the hardware. The principle is: that new bulb lamp mounted with 100mA of fuse, fit because fuse is triggered when the power light bulb inside zeroed using time counter. At the same time, the Sun in the fuse through a larger current will fuse. At this point machines into normal working condition. So if you get a new light bulb using time will automatically reset to zero. If you can not find the 100mA fuse can be shorted at both ends of the fuse location, power immediately after the boot, disconnect the power immediately after the boot, remove the short wire, the general success can also be cleared! Epson 730: Help key and keystone correction 'cut' key while pressing, there service menu, keystone correction key and press the Enter key can be cleared at the same time, there must be signals can operate Epson 33,003,500 clear method 1. . Open the lamp cover, check whether the locking lamp or bulb is destroyed. 2. . Whether the new light bulb to re-set after installation without them.In order to set the machine has two kinds of sorts: EMP-3300: soak the lights on after install bubble 鎖 good protection cover, this time with the time according to the projection machine Menu on the Sync button down and then soak the supply source to play after five seconds to open, and then open the second button Menu and Sync back open machine. EMP-3500: After the lock on the light bulb cover, this time on the projector while Anzhe Tracking + and Sync + keys then power on, after five seconds and then release Tracking + Sync + 2 keys you can reboot, and the remaining aircraft are not required to set. .


Maintenance of the brand to enter the menu of the projector method.


As the projector industry and the professional involved in more and stronger, and now we provide the maintenance menu (2 menu) from the patch, will help us further understanding of the projector and research, I hope we can know or own What is a good shortcut to write, but also all of us have a good learning environment;. .


Warning: it is strongly recommended that you do not alter parameters, as do you want to change, alter, it is recommended that you take the previous parameters, at least you can revert to the old looks;.


SONY (Sony):. .


Maintenance menu (for Sony most models): in standby, to ENTER, ENTER in the following order, direction, direction, press ENTER, and, after a corner S maintenance menu; the wording.


HITACHI (Hitachi):. .


See: power on, press RESET button for 3 seconds.


Maintenance menu: boot, click the menu, and then RESET button for 3 seconds;. .


Panasonic (Matsushita):.


92 out of the projector after the new menu options in the OSD open, and hold the ENTER key for 3 seconds into the maintenance menu;. .


EIKI, Sanyo:.


Read time: hold down the menu key 20 seconds;. .


Press the POWER key SU50 30 seconds in the time menu;.


LG projector:. .


Some models at the same time as the trapezoid correction key and menu key. (Also applicable to Morningstar some models).


EPSON (EPSON):. .


Method 1: most of the models of the maintenance menu: press the help key menu +;.


The second way: Press HELP key 3-5 seconds;. .


BENQ (BenQ):.


VP150 projector press and hold the EXIT 3 seconds into the lamp time, and then press the EXIT and direction;. .


Panasonic AE500 factory mode to enter cheat!..


And the AE300 is very similar, in MENU in the "other settings" (the company goods should be option) hold enter 5 seconds to enter the factory mode. .


The following flicker on the station adj discussed their adjustments (refer to the links below).


Whether desk (desk set) or ceiling (days suspended) default value and the optimal value:. .


Green: 2A (how are of no use, or will blink, blinking 2A is the smallest value).


Red: 2B (do not adjust very comfortable). .


-Blue: 27 (to the right to the 2D look the most comfortable).


Sharp AN200X way into the maintenance menu:. .


On the top, bottom, left, left, right, right, ENTER projector bulb, Edition number: 5.


BENQ 655 series machines to enter service menu mode:. .


Press and hold the direction keys, there will be time to dialogue, then while holding down the keys; AUTO + SOURCE.


Recommend that you do not move inside the data;. .


Canon (Canon) S2 series see the time machine (other type I cannot guarantee):.


Boot, press and hold the direction of the health 10 seconds;. .